Shandong, China
Business Type:
Manufacturer/Factory
Number of Employees:
36
Year of Establishment:
2007-11-07
Management System Certification:
ISO13485:2016
OEM/ODM Availability:
Yes
OEM/ODM Service
Sample Available
Japanese Speaker

Erythrocyte Sedimentation Rate, ESR, Automatic manufacturer / supplier in China, offering ESR Analyzer/ESR-2020/Diagnosis/Blood Sample/Medical Instrument, Bio&Media Alpha-Amylase (Alpha-AMY) Assay Kit/Test Kit/Ivd Reagent/EPS Method, Shandong Bio&Media Low Density Lipoprotein Cholesterol (LDL-C) Assay Kit/Ivd Reagent/Test Kit/Atherosclerosis of Coronary Artery and so on.

Gold Member Since 2018
Audited Supplier
Supplier Homepage Products Medical Diagnostic Equipment ESR Analyzer/ESR-2020/Diagnosis/Blood Sample/Medical Instrument
  • ESR Analyzer/ESR-2020/Diagnosis/Blood Sample/Medical Instrument
  • ESR Analyzer/ESR-2020/Diagnosis/Blood Sample/Medical Instrument
  • ESR Analyzer/ESR-2020/Diagnosis/Blood Sample/Medical Instrument
  • ESR Analyzer/ESR-2020/Diagnosis/Blood Sample/Medical Instrument

ESR Analyzer/ESR-2020/Diagnosis/Blood Sample/Medical Instrument

Get Latest Price
Min. Order / Reference FOB Price
2 Pieces US $1,000-1,300/ Piece
Port: Qingdao, China
Transport Package: Carton
Payment Terms: L/C, T/T, Paypal
Classification: Diagnostic Equipment
Type: ESR Analyzer
Certification: ISO13485
Group: Middle-aged and Old
Reading Channel: 20
Analysis Capacity: 20 Tests/30min

You Might Also Like

Loading...

Basic Info

Model NO.
ESR-2020
Application
Hospital, Lab
Trademark
Biomedia
Specification
300mm*400mm*300mm
Origin
Jinan, Shandong

Biomedia ESR-2020 is an automatic instrument controlled by microprocessors. Erythrocyte sedimentation rate (ESR) is analyzed by the advanced infrared monitoring and it is possible to conduct the measurement of dozens of  samples continuously and simultaneously. Every sample's sedimentary position could be tracked respectively together with a record of the whole analysis process. Advanced optical detector  and automatic temperature compensate could reduce the reading error of manual method as well as the errors caused by exterior factors effectively, such as timing error, oblique positioning and unstable or inappropriate room temperature .

Testing Principle
Infrared ray cannot be monitored if it is blocked by large amounts of red blood cells. When the cells gradually precipitate, infrared ray which goes through the blood-sedimentation tube can be detected by the receiver. The optical signals are converted into the electrical ones and the ESR values are calculated afterwards.

Product Features
  1. Easy operation: Simply put the ESR tubes into the positions, no extra data input
  2. Correlation: Automatic conversion into Westergren results (mm/h)
  3. Results correction: Automatic temperature compensation and correction, time correction
  4. Specimen safety: Closed measuring system prevents the contamination from the environment
  5. Fast and efficient: Eliminates specimen making, timing and other manual procedures;
  6. Flexible detection: Random determination of specimens at any time
  7. Specimen monitoring: Automatic alarming  to avoid the wrong results
  8. Consumables: Disposable ESR tubes, high cleanliness to guarantee the accuracy of the testing results
Technical Parameter

ESR Analyzer/ESR-2020/Diagnosis/Blood Sample/Medical Instrument


 

Send your message to this supplier

*From:
*To:
avatar Miss Yanan
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Loading...

Contact Supplier

Miss Yanan